Patients’ awareness of radiation dose and risks associated with medical imaging

In this article, the authors discuss how awareness of dose and risks of medical imaging by patients can facilitate shared decision making and reduce unnecessary radiation exposure.

Revolution CT Scanner at UW Medical Center Department of Radiology

 

New National Dose Levels Established for Common CT Exams

Dr. Kanal’s Research Establishes New National Dose Levels for Common CT Exams

Kalpana M. Kanal, Ph.D., a medical physicist, professor and section chief in diagnostic physics in the Department of Radiology at the University of Washington School of Medicine, Seattle, and colleagues examined actual patient data from the American College of Radiology (ACR) CT Dose Index Registry to develop size-based DRLs that enable healthcare facilities to compare their patient doses with national benchmarks and more effectively optimize CT protocols for the wide range of patient sizes they examine.

The use of DRLs have shown to reduce overall dose and the range of doses observed in clinical practice.

Dr. Kanal’s research is published here in Radiology.

This landmark work is very helpful in benchmarking CT dose levels. It will be widely cited, I predict. Congratulations, Kalpana!

Kalpana M. Kanal, Ph.D.

Adopting Best Practices for CT Radiation Dose Monitoring

In this article, the research conducted by University of Washington Radiology Fellow Dr. Achille Mileto and colleagues highlight the importance of dose monitoring, but also the challenges: “Successful efforts to reduce overall radiation doses may actually direct attention away from other critical pieces of information that have so far been underappreciated, namely the widespread variability in global radiation dose values across clinical operation volumes.” … “These data may provide a foundation for the future development of best-practice guidelines for patient-specific radiation dose monitoring.”

Dr. Achille Mileto from the University of Washington

“We are kind of obsessed with radiation dose reduction, but I think we should keep in our minds the concept of radiation dose optimization, which means trying to adjust the dose to the specific clinical task,” Mileto said. “With technology we are reducing the dose, but we are increasing the room for variability. This is great if you are consistently reducing the dose, but we really want to understand what’s going on in terms of variability. So I think the main lesson is to try to develop best-practice guidelines for patient-specific radiation dose monitoring. I think basically the scenario in the near-term future will be to create some kind of shared library for radiation doses.”

Ureteral Stones: Reduced-Dose CT Protocol in the Emergency Department

This recent article from Radiology reports the use of an 80% reduced dose CT protocol for assessing moderate to high risk patients for ureteral stones in an ED environment.

Reduced dose CT was correct for stone versus no stone in 100% of 108 patients. Dose reduction was achieved by lowering both the mAs and the kVp and adding iterative reconstruction.

CT colonography

Using model-based iterative reconstruction, CT colonography can be a very low radiation dose method of screening. This article applauds the United States Preventive Services Task Force (USPSTF) approval, cited as a “big win for patients.”

CT dose reduction in assessment of active Crohn’s disease

This article illustrates how iterative reconstruction can be used to markedly lower CT radiation dose without significant impact on diagnostic content in CT exams.

For patients with Crohn’s disease who likely will have multiple CT exams over time, lowering dose is especially important.

Decreasing radiation dose in CT for COPD patients

Study concludes that ultralow-dose CT may substitute for standard-dose CT in some COPD patients

There are at least three different generations of iterative reconstruction, all of which enable substantial CT dose reductions without compromise of diagnostic power. While earlier versions of IR yielded 30% dose reductions, those with model-based IR or some blend thereof can result in 50-80% patient radiation dose reductions – with even better spatial and low contrast resolution. Access the full article on this study.

Reducing dose via iterative reconstruction technology

As this article demonstrates, iterative reconstruction is a very powerful way to reduce dose without impacting diagnostic ability. Key points of the authors include, “To reduce patient and operator radiation dose involves optimization of medical imaging equipment and best control of the equipment by the operator. … The results of our study confirm in a large patient number reflecting the routine clinical setting that the image noise reduction technology allows a significant reduction in radiation dose.  … The substantially lower radiation dosage achieved in a routine clinical setting with the image noise reduction technique, provide further evidence of the substantial impact of the new technology. They indicate potential reduction in radiation dosage in invasive and interventional cardiology with more diffusion of newer radiation technology in clinical practice.”

Novel iterative reconstruction method for reducing CT dose

All iterative reconstruction techniques powerfully reduce CT radiation dose in the 40-80% range – without compromising diagnostic power. And they all continue to be refined and to evolve, as this article illustrates. While the “look” of CT images may change from the noise removal, the diagnostic power is not compromised despite the substantial dose reduction. As radiologists, working with change is our future. The old days of nothing but filtered back projection are in our history but not in our future.

The effect of trauma backboards on CT radiation dose

This article provides another neat bit of knowledge to consider when looking for lowest dose – though this is multi-factorial.

[Excerpt below]Backboard use in ED Figure 6

“Rate of backboard use during CT examinations of the chest–abdomen–pelvis performed in the ED from 1 January 2010 to 31 December 2012 (n=1532). Note the dramatic drop in backboard use in 2011 after multidisciplinary implementation of a policy for prompt removal of patients from backboards using primary clinical survey rather than waiting for a CT examination.”

Low-dose Radiation

Low-dose Radiation Not Harmful

To quote the American Association of Physicists in Medicine:

  • The risk from medical diagnostic radiation in doses below 50 mSv as a single dose or 100 mSv as a cumulative dose is too small to be measured and may be non-existent.
UW Medicine Physicists

UW Medicine Physicists

Detection of pulmonary nodules with low-dose CT and iterative reconstruction

This article illustrates how much good diagnostic information can be obtained using very low CT radiation doses when screening for lung nodules.

In the screening environment, doing no harm is especially important since so many patients are screened. But detection rates cannot suffer.

Here is encouragement that we can meet both goals with very low dose CT combined with iterative reconstruction.

Reducing dose for CT pulmonary angiography

Paying attention to limiting Z axis coverage yields big dose saving dividends! See this article for results of this study designed to assess the safety and efficacy of radiation dose reduction in hospitals lacking iterative reconstruction.

Gentle and wise use of CT radiation dose

This comprehensive article demonstrates the importance of CT dose monitoring and utilizing strategies to achieve ALARA (as low as reasonably achievable) doses while maintaining image quality for optimal clinical diagnosis. The authors also describe how the use of technology can improve the radiation dose efficiency of CT scanners.

Radiation Dose Management in CT: Is it easy to accomplish?

Guest blog by Kalpana M. Kanal, PhD, Direc­tor of Diag­nos­tic Physics Sec­tion and Asso­ciate Pro­fes­sor in the Depart­ment of Radi­ol­ogy at Uni­ver­sity of Washington

At the AHRA conference in Las Vegas recently, Dr. Pizzutiello, a medical physicist, discussed the complexity of CT radiation management and monitoring in diagnostic imaging. With the growing use of CT exams being performed and radiation dose in CT being a hot topic in the radiology community, it is imperative to monitor radiation dose from the CT exams as well as observe trends over time. Regulations now require that CT dose has to be documented and available on demand, CT protocols be revisited on an annual basis and incidents with high dose CT exams be reviewed. Several states around the US have CT regulations or are in the process of regulation implementation. It is a monumental task to monitor and manage dose, especially for large hospitals.

There are several dose management software products available that can help in managing the dose. Dose management is, however, a team effort and it is not possible to do this effectively without a team of radiologists, technologists, and medical physicists participating in this important task.

At our institution, we have been managing dose using a commercial product, Dose Watch (General Electric Healthcare) and also have a radiation safety committee within the department to review dose trends and make intelligent decisions based on our dose data. We have also been participating in the ACR CT Dose Index Registry since its inception and review our trends and benchmark values to our peer institutions. This is definitely a good idea if one is unaware of dose trends at their institution and how it compares to others around the nation.

Dose monitoring is complex but a necessary patient safety tool and, if well planned, can be accomplished and maintained with the help of dedicated professionals who understand the importance of the task.

The importance of dose alerts

At UW Medicine, we use a dose alert system built into DoseWatch (GE Healthcare) as well as in the individual CT scanners. While this is a good safety mechanism to prevent accidents and notice high dose exams, it’s not the whole answer. As this article points out, “… in practice, CT technique and therefore patient dose depends very much on patient size.”

Size specific dose exposure (SSDE) is a better measure which we will be hearing more about in the near future.

 

Low radiation dose without compromise of image quality

This article illustrates that Radiologists’ perceptions of image quality and content change as they become accustomed – over time –  to the different noise pattern of the various types of iterative reconstruction.

In fact, no spatial resolution or low contrast resolution is lost with iterative reconstruction techniques – and diagnostic power is maintained.

Our work here at UW Medicine agrees with this report.

And it is important to know this because iterative reconstruction can result in 30%-60% dose reduction for all types of CT, without loss of diagnostic power.

Radiation protection shielding

This article outlines the substantial reduction in radiation exposure to body parts which are shielded during a CT scan but not included in the field of imaging.

That is a very good practice.

More controversial is another practice: shielding sensitive body parts which ARE included in the field of imaging, specifically breasts, thyroid and gonads.

For some types of scanners this works well, while for other types less well.

With our scanners (GE) IF shielding to the sensitive body part is applied after the scout views are obtained, and IF the shield is separated from the body by placing towels or a blanket to elevate the shield off the body by 2-3 cm – then this works well. Any artifacts or other issues with image quality are minimal or out of the area of interest and the dose to the shielded body part does drop measurably.

Further, such shielding sends a strong message to patients and to our own staff about our concern for their safety.

Reducing radiation dose in diagnostic CT of the abdomen

Here’s a neat trick for dose reduction in appendicitis CT cases – which often are done in young patients.

It falls into the general category of only scanning as much Z-axis length as is needed to address a given indication –  and no more.

Achieving appropriate radiation dose for coronary CT angiography

This is an interesting addition to the sophistication of systematic lowering of kVp during CT coronary angiography. Of course, such sophistication strongly supports 30% dose reduction without compromising diagnostic power.

Reducing radiation dose for CT enterography

Since many patients who get CT enterography have repeated exams (inflammatory bowel disease, etc.), Model Based Iterative Reconstrucion has primarily been used to markedly reduce radiation dose while maintaining acceptable image quality.

However, this might be another application – especially if the patient will have only one such exam.

Optimizing Radiation Dose

Standardizing dose description parameters and metrics is an ongoing and very active area in ACR and nationwide. This will be a big help to comparing metrics between institutions and over time. The SSDE (Size Specific Dose Estimate) is a good step in that direction.

But this article also points out the large impact of exam appropriateness on dose. It is an impressive fact that a profound way to lower population dose is to avoid doing inappropriate exams. Tools such as the ACR Appropriateness Criteria or Computerized Decision Support at the point of order entry can empower appropriateness review. And every radiologist needs to increase their awareness of exam appropriateness in daily work.

Educating patients about radiation dose

The ultimate goal is to have a fully informed and well educated patient – this will result in best personalized healthcare and outcomes.

So as far as radiation dose from individual CT exams is concerned, it is good for patients to know what they received – but it is not enough. Patients also need to be educated about the meaning and risk of their radiation dose.

Educating patients about extremely low risk is difficult – as would be true about any very low risk. But, it should be coupled with educating patients about the potential health and healthcare benefits from their CT exam.

This is because what they really need to know is their risk/benefit ratio – from each CT exam. An educated patient who understands their risk/benefit ratio from CT will be a truly informed healthcare consumer.

Who should educate patients about risk and benefit? All of us – all providers. The primary care physician, the subspecialist, the radiologist, the CT technologist, the radiology nurse, PA’s and LPN’s – everyone who contacts the patient can help advance this education and this understanding.

MDCT 2014 speakers weighed in on this subject at the ISCT Symposium in early June.

Lowering medical radiation dose with CT and other modalities in cancer patients

It is often said that radiation from diagnostic imaging is not an important issue in cancer patients.

But this report suggests otherwise – as expressed by oncologists.

Many patients with cancer are young and/or are being treated for cure. Many have long life expectancies despite having cancer.

And the basic principal of “Do no harm” plus that of ALARA still apply – as much to cancer patients as to any other patient with a serious disease.

So we should be striving for maximal diagnostic information from minimal radiation dose with CT and other modalities in cancer patients, too.

A Radiologist Replies to ‘Medical Radiation Soars, With Risks Often Overlooked’

A few weeks ago, the New York Times featured an article, “Medical Radiation Soars, With Risks Often Overlooked.” The article brought up some valid points about radiation, but also requires readers to take a step back when processing some of the information given.

Yes, as the article ascertains, radiation has its indisputable medical advantages, in addition to its potential medical downsides. The amount of medical imaging, including CT scans, has significantly increased over the last few decades, as more life-saving procedures are discovered and as technology develops. As a result, some patients are subjected to higher levels of radiation, which, according to this article, is “believed to account or 1.5 percent of cancers” in the United States.

The piece goes on to say that “the cancer-causing effects of radiation are cumulative” and that doctors and hospitals fail to track the amount of radiation patients have already been exposed to when ordering a new exam. While it is critical to practice “As Low As Reasonably Achievable” (ALARA) for every protocol and to closely scrutinize every exam request for appropriateness, there is absolutely no evidence that risk from well spaced CT exams is cumulative. Therefore, canceling an otherwise appropriate exam because of cumulative dose may not be in the patient’s best interests. For all CT exams a risk/benefit evaluation should be made by a well informed radiologist. For the existence of multiple prior exams alone to change the risk/ benefit ratio would be extremely rare.

Additionally, the claim that “no one” keeps track of how much radiation patients have been exposed to is inaccurate. A number of institutions, including UW, are a part of the American College of Radiology’s Dose Index Registry, a program striving to accurately track CT radiation dose in order to establish benchmarks, monitor patient radiation dose exposure, and compare patterns. More recently, a pediatric dose registry was introduced to perform similar functions, but for a younger demographic.

Both doctors and patients should be as informed as possible when it comes to radiation. Understanding the risk/ benefit ratio is an important part of this—and no appropriate medical imaging exam should be cancelled if it will benefit the patient, especially if its radiation level is ALARA.

New Dose-Reduction Technique Optimizes Dose in Evolutionary Ways

At the recent International Society for Computed Tomography (ISCT) annual meeting, held in San Francisco, Dr. Eliot Siegel, from the University of Maryland, discussed an evolving technique for CT dose-reduction. This application does not focus on simulated image noise as a measure of image quality, but instead, works to more accurately depict that noise in low-dose CT scans. In other words, this technique aims to optimize dose based on what the radiologist needs to see.

According to the presentation, the future of low- dose optimization will rely on a combination of the visual perception system and sophisticated mathematical models designed to minimize the dose for every imaging exam without impairing the quality of the image to the radiologist. In fact, the current methods for low-dose optimization are already on the way out as awareness for radiation dose continues to evolve.

Dr. Siegel’s analysis of noise in the new world of iterative reconstruction is very sophisticated and thoughtful. Concepts of pink and white noise plus just-noticeable differences really are cutting edge. These ideas will clearly advance our understanding of how to get a world of fully automated dose minimization.

Dr. Siegel and his team of researches, as usual, are thinking profoundly and in very innovative ways. These concepts certainly raise great hope for a much more systematic future combined with much more sophisticated math to make patient doses even lower than we had previously dreamed! It will be an exciting next three years for dose reduction techniques and technology!

Dual- Energy CT: Less Radiation, Higher Image Quality

recent presentation at the 2011 International Society for Computer Topography (ISCT) meeting in San Francisco highlighted the effectiveness of using dual- energy CT for abdominal imaging. This CT- technique has become more promising for uncovering certain pathology that has otherwise been hidden by traditional diagnostic imaging procedures.

Dual- energy CT- by whatever technology – can be configured to employ less radiation than single energy CT. But for some specific applications, it produces more diagnostic and specific information. Dual- energy CT currently may be the best radiology technique for characterizing urinary tract stones to their chemical composition (which determines whether medical, shockwave, or laser therapy will be required), characterizing small renal masses, and characterizing liver masses into cyst versus tumor.

Additionally, dual- energy CT may apply to better detecting minimal liver tumors, lowering the amount of iodine needed for CT angiograms, and creating virtual non- contrast scans. The latter may reduce the overall CT radiation dose of a multi- phase study by 20 to 50 percent!

While dual- energy is still relatively new to the field, it is clear that it is a promising technique for CT dose reduction, while maintaining imaging quality. Further research and testing will be conclusive of the absolute benefits of dual- energy CT.

Discussing the Benefits of Low Dose CT Scans

Radiation is part of nature. We’re all exposed to radiation every day in very small amounts. But the amount of radiation being used for medical diagnosis has been increasing over the last 20 years or so – to a point where it is now raising new concerns about CT scan risks. In fact, the use of CT has increased over the last decade to the point where we’re now doing around 60 million CT scans a year in the United States.

So what does this mean for patients?

What other options are available to minimize the effects of CT scans?

How can patients go about trying to make smart decisions about the risks and benefits of CT scans?

Last October, I took part in a Webinar for Patient Power with medical physicist Dr. Kalpana Kanal that addresses these questions and more – touching on radiation dosage and risk, new technologies, and techniques for limiting exposure.

>watch the webinar